
Danfoss heat exchanger repair
Danfoss heat exchanger repair covers gasketed packs that can be rebuilt and brazed units that cannot. Send the nameplate and what has happened, and a specialist who works on that type will come back to you. Coverage is UK wide.
Tell us about your Danfoss heat exchanger repair
Five answers, all from memory. The detail comes next, and it is optional.
See the privacy notice for how these details are handled.
Common Danfoss heat exchanger problems
It has failed or is leaking
Fluids mixing, a leak at the unit, or one that will not hold pressure.
Emergency repair →Losing dutyPerformance has dropped
Higher pressure drop, a wider approach temperature, or a duty it no longer reaches.
Cleaning options →PlannedA service or shutdown is coming
Planned maintenance, an outage window, or a spare that needs to be ready.
Servicing options →UnsureNot sure what is wrong
Send the nameplate and what you have noticed. That is enough to get an answer.
Send the details →Danfoss units covered
Danfoss heat exchanger repair turns on one question before any other: whether the unit is gasketed or brazed. Danfoss supplies both, and they are opposite cases. A gasketed pack comes apart and can be rebuilt. A brazed unit is a sealed block that cannot be opened at all.
- Gasketed plate and frame units, which can be opened and rebuilt
- Brazed plate units, sealed and replaced rather than repaired
- Units badged Sondex, brought fully into Danfoss in 2016
- District heating, HVAC and industrial duties
What can be arranged for Danfoss units
- Strip, clean and rebuild on gasketed units
- Regasketing with the material matched to the fluid and temperature
- Chemical cleaning on brazed units where fouling is the problem
- Like for like replacement where a sealed unit has failed internally
Danfoss heat exchanger questions
Is my Danfoss unit repairable?
It depends which type it is. A gasketed unit has a frame, tie bars and visible plate edges with gaskets between them, and it can be opened and rebuilt. A brazed unit is a solid block with connections and nothing to undo, and a failed one is replaced.
Can a brazed Danfoss unit be cleaned?
Yes, chemically, while the unit is still sound. That is worth doing when performance has dropped. It is not a fix for a unit that has already failed internally, because the fault cannot be reached.
What information is needed?
The nameplate above all, then what has happened and whether the plant is running or down. A photograph of the plate answers the gasketed or brazed question immediately.
This site is not affiliated with, authorised by or endorsed by any manufacturer named on it. Manufacturer names and model designations are used only to identify the equipment a repair relates to.